Sandpiper G20 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pompy Sandpiper G20. SANDPIPER G20 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
s a n d p i p e r p u m p .c o m
Model G20
Metallic
Design Level 1
Natural Gas-Operated
Diaphragm Pumps
Certied Quality
Warren Rupp, Inc.
A Unit of IDEX Corporation
800 N. Main St.,
Manseld, Ohio 44902 USA
Telephone 419.524.8388
Fax 419.522.7867
SANDPIPERPUMP.COM
2.00
50.80
16.88
428.67
24.90
632.56
26.47
672.31
13.85
351.77
2.19
55.63
6.12
155.55
1" AIR EXHAUST PORT
11.63
295.28
2.24
56.84
10.00
254
5.00
127
2.25
57.15
24.90
632.56
2" NPT DISCHARGE PORT
2" NPT SUCTION PORT
9.00
228.60
R.25
6.35
12.25
311.15
10.00
254
10.06
255.59
3/4" NPT AIR INLET
BOTTOM VIEW
16.93
430.08
24.88
632.03
27.88
708.23
2.19
55.56
13.06
331.72
29.82
757.50
2.00
50.80
3.00
76.20
4X
.75
19.05
HOLES
1" NPT EXHAUST PORT
26.38
670.13
11.63
295.28
4.87
123.70
5.82
147.95
.67
17.07
2.00
50.80
25.04
635.97
16.00
406.40
7.99
202.89
4.00
101.60
2.00
50.80
4.99
126.69
10.00
254
2" RF 150# ANSI FLANGE
DISCHARGE PORT
2" RF 150# ANSI FLANGE,
SUCTION PORT
R.25
6.35
9.00
228.60
10.06
255.52
8.00
203.18
13.00
330.20
16.00
406.40
4.50
114.28
.50
12.70
MOUNTING HOLES
BOTTOM VIEW
AIR INLET
3/4" NPT
Quality System
ISO 9001 Certied
Environmental Management System
ISO 14001 Certied
Certied to CSA Technical Letter No, R-14
Certied to ANSI LC6-2008
© Copyright 2014 Warren Rupp, Inc.
All rights reserved
SERVICE & OPERATING MANUAL
Original Instructions
1: PUMP SPECS2: INSTAL & OP3: EXP VIEW4: Gas END5: WET END6: OPTIONAL7: WARRANTY
Przeglądanie stron 0
1 2 3 4 5 6 ... 20 21

Podsumowanie treści

Strona 1 - Model G20

s a n d p i p e r p u m p .c o mModel G20 Metallic Design Level 1 Natural Gas-Operated Diaphragm PumpsCertied QualityWarren Rupp, Inc.A Unit of IDE

Strona 2 - Grounding the Pump

sandpi p erpump .com7 • Model G20 Metallicg20mdl1sm-rev0614Troubleshooting GuideSymptom: Potential Cause(s): Recommendation(s):Pump Cycles OnceDeadhea

Strona 3 - Table of Contents

sandpi p erpump .comModel G20 Metallic • 8g20mdl1sm-rev0614Troubleshooting GuideSymptom: Potential Cause(s): Recommendation(s):Pump Cycles OnceDeadhea

Strona 4 - ATEX Detail

sandpi p erpump .com9 • Model G20 Metallicg20mdl1sm-rev0614Composite Repair Parts ListATEX Compliant LEGEND: = Items contained within Gas End Kits

Strona 5 - Materials

sandpi p erpump .comModel G20 Metallic • 10g20mdl1sm-rev0614Material Codes - The Last 3 Digits of Part Number000...Assembly, sub-assembly; and some

Strona 6 - Dimensional Drawings

sandpi p erpump .com11 • Model G20 Metallicg20mdl1sm-rev0614Gas Distribution Valve AssemblyATEX Compliant Valve Assembly for Aluminum Mid SectionsNatu

Strona 7

Pilot Valve Assembly Parts ListItem Part Number Description Qty4 095-110-000 Pilot Valve Assembly 14-A 095-095-157 Valve Body 14-B 755-052-0

Strona 8 - Principle of Pump Operation

Intermediate AssemblyINTERMEDIATE REPAIR PARTS LISTItem Part Number Description Qty5 114.024.157 Bracket, Intermediate 1 114.024.110 Bracket

Strona 9 - Top Discharge Ball Valve Pump

sandpi p erpump .comModel G20 Metallic • 14g20mdl1sm-rev0614Diaphragm Service Drawing, Non-OverlayDiaphragm Service Drawing, with OverlayMODEL SPECIFI

Strona 10 - Troubleshooting Guide

sandpi p erpump .com15 • Model G20 Metallicg20mdl1sm-rev0614Step 1: With manifolds and outer chambers removed, remove diaphragm assemblies from diaphr

Strona 11 - Service & Repair Kits

sandpi p erpump .comModel G20 Metallic • 16g20mdl1sm-rev0614When a diaphragm fails, the pumped liquid or fumes enter the natural gas end of the pump.

Strona 12 - Composite Repair Parts List

sandpi p erpump .comg20mdl1sm-rev0614IMPORTANTRead the safety warnings and instructions in this manual before pump installation and start-up. Failure

Strona 13 - RECYCLING

Declaration of ConformitySignature of authorized personDate of issuePrinted name of authorized personRevision Level: FTitleDavid RoseberryEngineering

Strona 14 - 4: AIR END

EC Declaration of ConformityIn accordance with ATEX Directive 94/9/EC, Equipment intended for use in potentially explosive environments.Applicable Sta

Strona 15 - Pilot Valve Assembly

sandpi p erpump .comg20mdl1sm-rev0614Table of ContentsSECTION 1: PUMP SPECIFICATIONS ...1 • Explanation of Nomenclature • Performance

Strona 16 - Intermediate Assembly

II 2GD T5II 1G c T5II t G c T5II 1D c T100°C †I M1 cI M2 cModels equipped with Wetted Option S Non-Wetted Options S, T, 7, 8, or 9, Pump Option X.No

Strona 17 - MODEL SPECIFIC

sandpi p erpump .comModel G20 Metallic • 2g20mdl1sm-rev0614PerformanceG20 METALLICSUCTION/DISCHARGE PORT SIZE• 2"CAPACITY• 0 to 150 gallons per m

Strona 18 - Diaphragm Servicing

sandpi p erpump .com3 • Model G20 Metallicg20mdl1sm-rev0614G20 Metallic Dimensions in inches (mm dimensions in brackets). Dimensional Tolerance:±1/8&

Strona 19 - PUMPING HAZARDOUS LIQUIDS

sandpi p erpump .comModel G20 Metallic • 4g20mdl1sm-rev0614G20 Metallic - ANSI Flange Dimensions in inches (mm dimensions in brackets). Dimensional T

Strona 20 - Declaration of Conformity

sandpi p erpump .com5 • Model G20 Metallicg20mdl1sm-rev0614Gas-Operated Double Diaphragm pumps are powered by compressed gas, nitrogen or natural gas.

Strona 21 - EC Declaration of Conformity

sandpi p erpump .comModel G20 Metallic • 6g20mdl1sm-rev0614Installation And Start-Up Locate the pump as close to the product being pumped as possible.

Komentarze do niniejszej Instrukcji

Brak uwag